Series : LA100P Measurement : Current Nominal Value : 100 A Measuring Range : 150 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 50 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : LA200P Measurement : Current Nominal Value : 200 A Measuring Range : 300 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 100 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAS200-S Measurement : Current Nominal Value : 200 A Measuring Range : 600 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : LA305S Measurement : Current Nominal Value : 300 A Measuring Range : 500 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 120 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : LA55P Measurement : Current Nominal Value : 50 A Measuring Range : 100 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 25 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAS 50-S Measurement : Current Nominal Value : 50 A Measuring Range : 150 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAS500-S Measurement : Current Nominal Value : 500 A Measuring Range : 900 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : LA25P Measurement : Current Nominal Value : 25 A Measuring Range : 55 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 25 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage Range...
Series : HAS300-S Measurement : Current Nominal Value : 300 A Measuring Range : 900 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAS600S Measurement : Current Nominal Value : 600 A Measuring Range : 900 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAS100-S Measurement : Current Nominal Value : 100 A Measuring Range : 300 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAT600-S Measurement : Current Nominal Value : 600 A Measuring Range : 1800 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAT200-S Measurement : Current Nominal Value : 200 A Measuring Range : 600 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAS400-S Measurement : Current Nominal Value : 400 A Measuring Range : 900 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAT400-S Measurement : Current Nominal Value : 400 A Measuring Range : 1200 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : HAT800-S Measurement : Current Nominal Value : 800 A Measuring Range : 2400 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series:LF305Measurement:CurrentNominal Value : 300 AMeasuring Range : 500 ASecond. Nominal Signal : CurrentSecond. Nominal Signal ValueInstantaneous 150 mAPrimary Signal : AC + DCSupply Voltage : External DC BipolarSupply Voltage Range12 - 20...
Series : HAT1000-S Measurement : Current Nominal Value : 1000 A Measuring Range : 2500 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series : LF505Measurement : CurrentNominal Value : 500 AMeasuring Range : 800 ASecond. Nominal Signal : CurrentSecond. Nominal Signal ValueInstantaneous 150 mAPrimary Signal : AC + DCSupply Voltage : External DC BipolarSupply Voltage Range12 - 20...
Series : HAT1200-S Measurement : Current Nominal Value : 1200 A Measuring Range : 2500 A Second. Nominal Signal : VOLTAGE Second. Nominal Signal Value : Instantaneous 4 V Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...
Series :HAT1500-S Measurement:Current Nominal Value:1500 A Measuring Range:2500 A Second. Nominal Signal:VOLTAGE Second. Nominal Signal Value:Instantaneous 4 V Primary Signal:AC + DC Supply Voltage Range:15-15V
Series : LTS25-NP Measurement : Current Nominal Value : 8 A, 12 A, 25 A Measuring Range : 80A Second. Nominal Signal : Voltage Second. Nominal Signal Value : Instantaneous 150 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply...
Series : LA306-S Measurement : Current Nominal Value : 300 A Measuring Range : 700 A Second. Nominal Signal : Current Second. Nominal Signal Value : Instantaneous 150 mA Primary Signal : AC + DC Supply Voltage : External DC Bipolar Supply Voltage...